Hat Channel: Sizes, Uses and Installation

Hat channel used as a surface to attached corrugated metal panels to

US Frame Factory manufactures and supplies hat channel for commercial cold-formed steel framing projects across the United States. Also called furring channel, this hat-shaped steel member creates a consistent attachment surface for wall and ceiling finishes, supports selected exterior assemblies and can provide bracing when it is specified as part of an engineered system.

Our current steel framing product catalog lists two profile depths and multiple gauge options. Use the tables below to identify a starting point, then confirm the final member, length, coating, spacing, connections and quantity against the project drawings and applicable submittal.

Need pricing or product-selection support? Send us your plans or project requirements for current availability, lead times and manufacturer-direct pricing. Or call (337) 282-5877 to discuss your hat channel order.

Available Hat Channel Sizes and Gauges

The profile depth changes the space created between the substrate and the finish, while the gauge affects the member’s stiffness and capacity. Selection should be based on the complete assembly—not gauge alone.

Profile depthCatalog designationPublished gauge options
7/8 inch87F12525 gauge, 20 gauge EQ, 20 gauge, 18 gauge, 16 gauge and 14 gauge
1.5 inches150F12525 gauge, 20 gauge EQ, 20 gauge, 18 gauge, 16 gauge and 14 gauge

Current Catalog Member Numbers

Gauge description7/8-inch profile1.5-inch profile
25 gauge87F125-15150F125-15
20 gauge EQ87F125-18150F125-18
20 gauge87F125-30150F125-30
18 gauge87F125-43150F125-43
16 gauge87F125-54150F125-54
14 gauge87F125-68150F125-68

The catalog currently links product submittals for 87F125-30, 150F125-30, 87F125-43 and 87F125-54. Those submittals list a 1.25-inch top width and 2.75-inch base width for those published profiles. Because submittals are member-specific, confirm geometry, steel properties, coating and allowable use from the sheet issued for the exact product you plan to specify.

Catalog Listing vs. Quote Availability

A catalog listing confirms the published profile range, not stock on a specific day or a guaranteed production date. Ask our sales team to confirm the exact length, coating, bundle quantity, lead time and freight for the delivery location. For phased projects or multiple buildings, separate quantities by release and note the required onsite date for each shipment. This gives production and logistics teams enough detail to price the order and identify schedule conflicts before material is released.

How to Read a Hat Channel Member Number

Member designations put essential profile information into a compact code. For example, 87F125-30 identifies:

  • 87: nominal profile depth of 0.875 inch, or 7/8 inch
  • F: furring channel profile
  • 125: 1.25-inch top width
  • 30: 30-mil design thickness

The same system makes 150F125-30 a 1.5-inch-deep furring profile with a 1.25-inch top and 30-mil design thickness. For more examples, review our guide to metal framing member nomenclature.

Gauge names can be useful shorthand, but the mil thickness and complete member designation provide clearer specification information. This is especially important when distinguishing equivalent-gauge products from conventional members or coordinating submittals across the project team.

Common Hat Channel Uses

Hat channel is useful wherever a project needs a straight, repeatable attachment plane, a controlled cavity or a specified bracing member. Common applications include:

Furring Concrete or CMU Walls

Uneven concrete and masonry surfaces can make finish installation difficult. Hat channel creates a uniform plane that accepts gypsum board, plaster bases or other approved finishes. The cavity may also help coordinate insulation or limited service space when the wall design allows it.

Ceiling Furring and Suspended Assemblies

Furring channel can form the attachment grid for gypsum ceilings and selected suspended systems. The profile, gauge, spacing and supporting members must be coordinated with the ceiling weight, span, deflection criteria and connection details.

Curtain Wall Furring and Exterior Cladding Support

A specified channel can support sheathing or cladding attachment and create a cavity behind the finish. Exterior use requires a complete wall design that addresses loads, drainage, ventilation, corrosion exposure, compatible fasteners and continuity of the water, air and thermal control layers.

Truss Bracing

Hat channel may provide lateral restraint for trusses when it appears in the engineered bracing plan. Bracing is structural work: member size, orientation, laps and connections must follow the truss designer’s or engineer’s details.

Other Project-Specific Applications

Depending on the design, furring channel may support siding, decking or specialty finish systems. Do not assume that one profile suits every application. Confirm the substrate, supported material, loads and exposure before ordering.

Specification Considerations

A useful quote or submittal starts with more than a gauge. Confirm these items before final selection:

  • Application: wall furring, ceiling framing, cladding support, truss bracing or another use
  • Profile depth: 7/8 inch or 1.5 inches
  • Member and thickness: complete designation, gauge and mil thickness
  • Span and spacing: based on supported loads, deflection limits and published design information
  • Substrate: concrete, CMU, structural framing, cold-rolled channel, truss chord or another approved support
  • Finish or supported material: gypsum board, plaster base, sheathing, siding or another system
  • Connections: fastener or clip type, size, spacing and edge-distance requirements
  • Environment: interior, exterior, conditioned, wet or corrosive exposure
  • Coating: project-specified metallic coating and compatibility with adjacent materials
  • Length and quantity: required piece lengths, takeoff quantities and packaging needs
  • Documentation: drawings, specifications, submittals, material test reports or other project requirements

Published submittals for listed structural furring members reference ASTM A653 and ASTM A1003 material standards, the SSMA Technical Guide and identified building-code editions. The design professional and authority having jurisdiction determine which standards, code edition and acceptance documents apply to a particular project.

Installation Planning

Installation details change with the assembly. Use this sequence to coordinate the work without replacing the approved drawings, manufacturer data or engineer’s instructions.

  1. Verify the assembly. Confirm the selected profile, gauge, orientation, spacing and finish system before material is released.
  2. Review the substrate. Identify substrate condition, fastener suitability, embedment limitations and any required isolation between dissimilar materials.
  3. Establish the finished plane. Lay out reference lines and shims or stand-offs, where approved, so the completed grid is straight, level and plumb.
  4. Install specified connections. Use only the clips, screws, anchors, welds or tie wire called for by the assembly details. Do not substitute fasteners based on convenience.
  5. Coordinate joints and openings. Follow the approved requirements for ends, laps, penetrations, corners, control joints and perimeter conditions.
  6. Inspect before covering. Check alignment, attachment, damaged coating and interference with other trades before finishes conceal the framing.

For direct furring over concrete or CMU, channels are commonly installed vertically so the finish can be fastened across a consistent plane. In ceiling assemblies, their direction and support layout depend on the carrying channels or structure above. Exterior and bracing applications require project-specific details; there is no universal orientation or spacing that is safe for every condition.

Hat Channel Compared With Resilient Channel and Z-Furring

These profiles are not interchangeable.

ProductTypical purposeImportant distinction
Hat/furring channelCreates a finish attachment plane, cavity or specified braceSymmetrical hat-shaped profile offered in multiple depths and gauges
Resilient channelHelps decouple finishes from framing in tested acoustic assembliesPerformance depends on the complete tested assembly and correct orientation
Z-furringFurs out masonry or concrete and can accommodate insulationZ-shaped profile creates a different attachment geometry and cavity depth

Choose the profile identified in the project documents. Substituting one channel type for another can change attachment, fire, acoustic, moisture or structural performance.

Frequently Asked Questions

Are hat channel and furring channel the same thing?

In most North American framing specifications, the terms describe the same hat-shaped furring profile. Always confirm the complete member number because depth, width and thickness vary.

How deep is hat channel?

Our current catalog lists 7/8-inch and 1.5-inch profiles. The depth is the first part of the member designation: 87 indicates 0.875 inch, while 150 indicates 1.5 inches.

Does hat channel run vertically or horizontally?

Orientation depends on the assembly. Direct wall furring is commonly vertical, while ceiling, cladding and bracing layouts follow the support direction and approved design details. Use the project drawings rather than a universal rule.

Can hat channel be used outside?

It can be part of an exterior assembly when the member, coating, fasteners and connections are designed for the loads and exposure. The complete wall must also manage drainage, ventilation, corrosion and control-layer continuity.

How do I request a quote?

Provide the profile depth, member number or gauge, lengths, quantities, application and delivery location. Include drawings, specifications and required submittals when available so we can review the exact project requirements.

Request Hat Channel Pricing and Submittals

Tell us which profile, gauge, length and quantity you need, where the material will ship and how it will be used. If the selection is still being coordinated, include the plans and specifications so our sales and technical team can help identify the correct published data and current availability.

Request project pricing from US Frame Factory or call (337) 282-5877 to discuss your hat channel order.

Leave a Reply

Your email address will not be published. Required fields are marked *